Assessments of House Damage from Event Dial Pack and 100 Ton AN/FO Test
Abstract
The report summarizes the damage sustained by a two-story wood-frame house exposed to a peak incident overpressure of about 1.6 psi from the explosion of a hemispherical charge of Ammonium Nitrate/Fuel Oil (AN/FO) weighing 100 tons, and - after being moved and repaired - to a peak incident overpressure of about 2.7 psi from the explosion of a 500-ton spherical charge of TNT tangent to the ground surface (Event Dial Pack). A moderate amount of damage (including considerable roof rafter damage) was noted after the AN/FO test; considerably more damage (including breakage of all roof rafters) was noted after the Dial Pack test.
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 01, 1972
- Accession Number
- AD0739371
Entities
People
- C. Wilton