The U.S. Army Combat Capabilities Development Command (DEVCOM) Armaments Center (AC), Picatinny Arsenal, NJ, has conducted the small-scale gap test (SSGT) on hundreds of explosive formulations in the last several decades. While test facilities and personnel have changed over this timeframe, the basic test method to assess shock sensitivity in this configuration has remained the same. DEVCOM ACs approach differs from the current governing document [Allied Ordnance Publication (AOP)-7]. This report will detail the key differences between the DEVOM AC method and AOP-7, Edition 2. Additionally, the output from varying explosive column heights in the donor charge was assessed and reported.