Thirty-two tests were conducted to determine the safe clear spacing between conveyor fixture trays containing 16 loaded 105-mm projectile funnels (with Composition B filled risers). These tests simulated the passage of the conveyor trays through the ramp connecting the Funnel Pulling Buildings (E-133 and E-134) and the Riser Melt Building (E-9) at the Lone Star Army Ammunition Plant, Texarkana, Texas. Four of these 32 tests utilized aluminum or steel plate shields. However, further testing with shields was discontinued since an unshielded clearance of 3.66 m (12 ft) between two adjacent trays was found to be safe and will meet production requirements as well. The safety of the 3.66-meter separation was verified by confirmatory testing. (Author)