Reliability Test Report. Modular Cryogenic Generator.
Abstract
Reliability Testing of the LOX-30 Liquid Oxygen Plant was evaluated in accordance with MIL-STD-781. Reliability Tests were divided into Environmental Requirements, Reliability Growth and Reliability Demonstration Tests. Accept/reject criteria for the demonstration test was a specified MTBF of 1900 hours at the 30% risk level which was met. Four non-relevant failures occurred but had minor effect on the LOX-30 system. A failure distribution was established for the electro-pneumatic solenoid valves to be Log-normal. (Author)