Development Report for High-Reliability, Low-Cost Integrated Circuits.
Abstract
Wafer fabrication has been completed. The control units (aluminum metallized DIC and DIP devices and trimetal devices in open DIC packages) are 90-percent complete. Thermal-shock testing of HRLC (high-reliability, low-cost) product has defined a beam-tape design problem which has necessitated the redesign of the beam tapes on all types. Life-test matrices have been run on CD4012 and CA741 to gain a preliminary insight into the failure modes to be expected in Phase III. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Sep 03, 1978
- Accession Number
- ADA062706