Determination of Digital Control System Response by Cross-Multiplication.
Abstract
This report describes the Cross-Multiplication technique for obtaining the response of a digital control system from its closed-loop transfer function. When the latter is expressed in the complex z-domain, the response is obtained at the sampling instants. If it is desired to know the response between the sampling instants, the submultiple method may be adapted to the cross-multiplication technique. When the transfer function is expressed in the modified z-transform domain, the response is obtained at any point within each sampling instant. The three approaches are described and applied to an example. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- May 29, 1979
- Accession Number
- ADA075745
Entities
People
- S. M. Seltzer
Organizations
- United States Army Aviation and Missile Command