Application of Graphite/Epoxy Composites for the SPS-10 Radar Reflector.
Abstract
The General Dynamics Convair Division evaluated the applicability of graphite/epoxy on the SPS-10 radar reflector. The effort began with a study of the RF performance of a graphite/epoxy grating panel, which proved to perform as well as its metal counterpart. A composite prototype unit of the reflector unit was designed fabricated and tested for performance approval. The graphite/epoxy reflector was mounted on a Navy-furnished SPS-10 spider and pedestal for structural (wind and vibration) and RF pattern range testing. All performance test results met or exceeded Navy specifications. Following testing at General Dynamics, the antenna was sent to the Naval Ocean Systems Center for extended RF and environmental testing prior to shipboard evaluation. (Author, modified -PL).
Document Details
- Document Type
- Technical Report
- Publication Date
- Oct 01, 1979
- Accession Number
- ADA077530
Entities
People
- Gary A. Tremblay
Organizations
- General Dynamics