Prediction of 3-D Blast Loading on a Partially-Open Industrial Building: Feasibility Study.
Abstract
The modified 3-D HULL hydrocode is used to calculate the blast loading on a partially-open, industrial-type building struck by a 32.8 kPa (4.75 psi) overpressure shock at oblique incidence. The feasibility of predicting the net unsteady loading on the front and back walls of the building is demonstrated. The predicted loading appears to be qualitatively correct; further studies will be necessary to assess the quantitative results and extend the analysis to other types of structures. (Author)
Document Details
- Document Type
- Technical Report
- Publication Date
- Jul 01, 1981
- Accession Number
- ADA104380
Entities
People
- Clarence W. Kitchens Jr.
- John D. Wortman
- Richard E. Lottero
Organizations
- Ballistic Research Laboratory