Impact Sensitivity of Han-Based Liquid Propellants at Elevated Temperatures
Abstract
A Technoproducts drop weight tester was used to evaluate impact sensitivity of four liquid monopropellants; OTTO II, NOS 365, LP 1845 and LP 1846. The monopropellants were evaluated for impact sensitivity at ambient temperatures and at temperatures in excess of 50 C. The propellants were all relatively insensitive to impact compared to the calibration liquid n-propyl nitrate at ambient temperatures. The impact sensitivity increased slightly for the HAN-based monopropellants at temperatures up to 50 degrees. The impact sensitivity of OTTO II increased dramatically as a function of increased temperature.
Document Details
- Document Type
- Technical Report
- Publication Date
- Mar 01, 1988
- Accession Number
- ADA194678
Entities
People
- Bruce D. Bensinger
- Irvin C. Stobie
- John D. Knapton
Organizations
- Ballistic Research Laboratory