Part I: Pilot Test Work Plan for SWMU #70 - Oil/Water Separator No. 326, Cannon AFB, New Mexico. Part II: Interim Pilot Test Results Report for SWMU #70 - Oil/Water Separator No. 326, Cannon AFB, New Mexico
Abstract
This work plan presents the scope of multiphase bioventing pilot tests for in situ treatment of fuel-contaminated soils at solid waste management unit (SWMU) #70 - Oil/Water Separator No. 326 at Cannon Air Force Base (AFB), New Mexico. The location of the sites with respect to the base is shown on Figure 1.1. The pilot test will be performed by Engineering-Science, Inc. (ES). The three primary objectives of the proposed pilot test are: 1) to assess the potential for supplying oxygen throughout the contaminated soil interval, 2) to determine the rate at which indigenous microorganisms will degrade fuel when supplied with oxygen-rich soil gas, and 3) to evaluate the potential for sustaining these rates of biodegradation until fuel contamination is remediated to concentrations below regulatory standards.
Document Details
- Document Type
- Technical Report
- Publication Date
- Aug 01, 1994
- Accession Number
- ADA384848
Entities
Organizations
- Parsons Corporation