Unshielded Facility Nondestructive Inspection (NDI) Radiation Protection Survey for Homestead ARB, FL
Abstract
Radiation protection survey of the aircraft wash-rack used for unshielded NDI operations at Homestead ARB. The NDI personnel used a Lorad LPX-160 x-ray unit for inspections. Survey was performed in accordance with T.O. 33B-1-1 and applicable Air Force standards. The aircraft wash-rack was recertified as an "unshielded facility."
Document Details
- Document Type
- Technical Report
- Publication Date
- Sep 09, 2013
- Accession Number
- ADA590117
Entities
People
- Michael Ames
- Phillip Heil
- Zahid Sulaiman
Organizations
- United States Air Force School of Aerospace Medicine