CONVENTIONAL PHYSICAL SECURITY At the request of the Under Secretary of Defense (Intelligence) (OUSD (I)), the DoD Lock Program conducted tests on existing magazine door designs. Results indicate many doors provide less than 10 minutes of resistance against attacks using commercially available tools. Therefore, security for current storage magazines must rely heavily on manpower to keep adversaries from gaining access to sensitive assets. The purpose of this project is to develop design criteria, for new construction and to retrofit existing structures, to provide 10 minutes of forced entry protection. Supporting Requirement Documents: Tier 1 - 2.1.1.1 IUBIP ICD JAN08, Capability Gap Priority 19, DoDD 5100.76M.